Stainless Steel Expansion Joints

Single Articulated Expansion Joints

Product Code: BFC/N

EMFLEX single articulated expansion joints (also known as single ‘untied’ or ‘tied’ flexible connectors) are used to absorb vibration in pumped systems and misalignment in pipework systems. They are usually installed at the pump suction and discharge connections. The tie rods prevent elongation due to the internal pressure thrust. The units are not intended to absorb vibration and misalignment simultaneously. Axial thrust must not be applied to these units, for example when pipework is mounted vertically from the unit. In this situation the pipework should be supported using spring supports.

Product Type

Info Table

Additional Information

TYPE BFC

For use on steel pipelines and is suitable for steam and hot water for heating. This unit has stainless steel bellows and inner sleeve with carbon steel ‘untied’ or ‘tied’ flanges.

TYPE BFCN

For use on copper pipelines and is suitable for condensate and domestic hot water. This unit has stainless steel internals comprising stainless steel bellows, inner sleeve and van-stone ends with carbon steel ‘untied’ or ‘tied’ backing flanges.

  • Nominal Size
  • mm
  • 50
  • 65
  • 80
  • 100
  • 125
  • 150
  • 200
  • 250

 

  • Installed Length
  • mm
  • 130
  • 130
  • 130
  • 130
  • 150
  • 150
  • 200
  • 200

 

  • Vibration Movement
  • +/-
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75

 

  • Lateral Deflection at 10 bar
  • mm
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2

 

Working Pressure: 16 bar (1600 kPa).

 

Test Pressure: 1.5 x Working Pressure.

Press./Temp. ratings for carbon steel PN16 Flanges.

Design Temperature x Working Pressure

{(ºC)} {120} {150} {200} {250} {300}

{Bar} {16} {14} {12} {11} {9}

Material Specifications

Bellows and internal sleeve are stainless steel. For steel service the flanges and tie rods are carbon steel. For copper service van-stone ends are stainless steel; backing flanges and tie rods are carbon steel.

Design Consideration

Single tied flexible connectors are used on high temperature pumps etc where conventional rubber flexible connectors do not have sufficient temperature capability (i.e. above 100ºC). They are usefully employed to relieve stresses on boiler crown valves and other vulnerable plant connection points.

+ -

Emflex

Stainless Steel Expansion Joints

N.Minikin & Sons Limited

Unit 2B Brickyard Road, Roecliffe, York, YO51 9NS
Email: enquiries@minikins.co.uk Web: www.minikins.co.uk
Tel: 01423 326 789

01423 326 789

N.MINIKINS & SONS LIMITED

MINIKINS.CO.UK

Single Articulated Expansion JointsProduct Code: BFC/N

EMFLEX single articulated expansion joints (also known as single ‘untied’ or ‘tied’ flexible connectors) are used to absorb vibration in pumped systems and misalignment in pipework systems. They are usually installed at the pump suction and discharge connections. The tie rods prevent elongation due to the internal pressure thrust. The units are not intended to absorb vibration and misalignment simultaneously. Axial thrust must not be applied to these units, for example when pipework is mounted vertically from the unit. In this situation the pipework should be supported using spring supports.

TYPE BFC

For use on steel pipelines and is suitable for steam and hot water for heating. This unit has stainless steel bellows and inner sleeve with carbon steel ‘untied’ or ‘tied’ flanges.

TYPE BFCN

For use on copper pipelines and is suitable for condensate and domestic hot water. This unit has stainless steel internals comprising stainless steel bellows, inner sleeve and van-stone ends with carbon steel ‘untied’ or ‘tied’ backing flanges.

  • Nominal Size
  • mm
  • 50
  • 65
  • 80
  • 100
  • 125
  • 150
  • 200
  • 250

 

  • Installed Length
  • mm
  • 130
  • 130
  • 130
  • 130
  • 150
  • 150
  • 200
  • 200

 

  • Vibration Movement
  • +/-
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75
  • 0.75

 

  • Lateral Deflection at 10 bar
  • mm
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2

 

Working Pressure: 16 bar (1600 kPa).

 

Test Pressure: 1.5 x Working Pressure.

Press./Temp. ratings for carbon steel PN16 Flanges.

Design Temperature x Working Pressure

{(ºC)} {120} {150} {200} {250} {300}

{Bar} {16} {14} {12} {11} {9}

Material Specifications

Bellows and internal sleeve are stainless steel. For steel service the flanges and tie rods are carbon steel. For copper service van-stone ends are stainless steel; backing flanges and tie rods are carbon steel.

Design Consideration

Single tied flexible connectors are used on high temperature pumps etc where conventional rubber flexible connectors do not have sufficient temperature capability (i.e. above 100ºC). They are usefully employed to relieve stresses on boiler crown valves and other vulnerable plant connection points.

01423 326 789

N.MINIKINS & SONS LIMITED

MINIKINS.CO.UK

Our EMFLEX Stainless Steel Expansion Joints are single articulated and come ‘tied’ or ‘untied’ to meet the requirements of your pipework systems. This product is used to solve issues caused by plant machinery, such as pumps, through absorbing movements that may otherwise damage pipework. It’s important to note that this product is not to be confused with our thermal expansion bellows, which cater for thermal movements in pipework.

To learn more about this product, simply explore the data sheets provided or get in contact with one of our experts to receive your free enquiry for any project.

Comments are closed.

  • Get A Free Consultation